Is QC3 enough?

I haven't finished it yet but I am in a similar boat as you. My plan was a little different but not much. I plan on putting the QC3 at the end of the run with a series of 1" copper lines running vertical, where the top of the "sets" of pipes are tied together, and the "sets" are tied together at the bottom. Basically the air has to snake up and down the pipe to get thru to the other end. At the bottom of each set is a 1' drop with a ball valve on it so that I can drain the water out in several locations. I also plan on having two outlets, one with a cheap filter and regulator for regular air tools, and another with the QC3 that is strictly for painting. Total length of pipe is 60' of 1" and another 15' of 3/4" after the 1" grid to the drop. The 1" will be spaced off of the back wall of the garage which is a concrete wall that is buried on the outside so it always stays cooler than the rest of the garage.

In my head it all works based on what I have read on other forums, but I have yet to actually apply it in the real world.

I am not sure what the rule is on posting links to other forums so if you want to know where I got the info I did pm me and I will tell you where.

Jason