MSD 6al issues - bypass ballast resistor
blue ignition 1 wire is powered key in run position, brown ignition 2 is powered key in start position. crimp together and use this to feed the msd 12 volts switched ignition feed. also make sure polarity for the magnetic pickup is correct if using oem dizzy. if polarity is reversed it will be hard to start and run poorly.