Voltage regulator upgrade? Keep frying voltage regulators with swap

i found two pictures

not sure how much they will help



View attachment 1714691838

it seems like you are pretty much wired this way already...

Correct.

The car has 2200 miles on it. It's been through 3-4 voltage regulators. No failures under light load, only under heavy electrical load.

Leads me to believe I need a 'better' VR. Heavy Duty. anything.


You said this:





This MEANS one of two things:

1....either this alternator DOES HAVE an internal regulator

2...or there is some sort of field short or wiring problem that is causing the regulator to be essentially ineffective

This also means.........

1...that if internally regulator, whatever regulators you are buying are not needed and incorrect

2...that in any case the external regulator is NOT the root cause of this problem, even though it may be failing. The "actual" problem is the cause of the regulator failing.

OR that the external VR failed in the 'charge' position...