Bypass OE ampmeter

I just run a length of 10-12 gauge wire with suitable 14-16 gauge piece of fusible link from the starter relay lug to the alt lug. It takes the load off the ampmeter and the bulk of the charging circuit no longer runs through the bulkhead connector/dash and back out again. Then I just hookup a good aftermarket voltmeter. Done.