How to adjust roller rockers w/ hydraulic cam. First start up.

You can't adjust pre-load on hydraulic lifters with them "pumped up". You have to adjust them dry or after they have bled down.

Well sure you can. Simply back off the adjuster and add some clearance, tighten until zero then adjust your preload. You can still adjust all day long with the lifters pumped up. You will just open the valves a hair for a moment or two. They will bleed right back down before you are even finished.