Voltage problems, cutting out when hot
So doing more probing I found that with the ignition switch unplugged testing at each pin there is 12.x (same as batt) at the blue pin to bulkhead and 11.x at the yellow pin in the same connector.
I traced that wire to the bulkhead connector, disconnected (again) and tested the yellow wire from the unplugged connector and it reads the same 11.x then traced it to the starter relay where it reads 11.x with the ignition switch still unhooked.
Ignition switch hooked up and key off
Key on (not running)
Ignition switch unhooked
So with the yellow wire unhooked at the starter solenoid that terminal reads about the same... isn’t this terminal supposed to only have voltage at start?