No start on rebuilt 360LA

From what the pics show, here are my observations.

1. The cap appears to be wired for #1 to coincide with the rotor position in the distributor as pictured.

2. The timing mark is about 9-10 degrees after TDC. Is it #6 or #1 ATDC?

3. The intake valve is open at that point. Should it be?

DAMN!!! You got way more out of that than I did!!! I completely spaced looking at the valves!!! I agree with this assessment.