Fan relay and sniper install

I would leave the green wire off relay 1 & Relay 2 black relay switch wire connect to Holley Sniper see below

10 Pin Connector – Mating Harness PN 558-491, 8 wires are populated. This connector contains: Pin Color Labeled Name Function A Orange Input #1 (-) Optional - Connect to a ground triggered A/C relay B Yellow Input #2 (-) Optional - Connect to a programmable ground input C Light Blue Output #1 (-) Optional – Connect to Fan #1 relay ground trigger D Light Green Output #2 (-) Optional – Connect to Fan #2 relay ground trigger
Yellow connect to a ground triggered relay if you cannot find connect a spare relay coil across the positive & negative clutch wire on the compressor then connect 87 to ground & 30 to yellow sniper A/C trigger wire so when you turn on the Air relay will close & connect Yellow Sniper wire to ground

Ill re read this one in the morning. Im pretty bad at this stuff and to add to the confusion ....the relay pack from derale does not have numbers on it.