AC troubleshoot

RV2 was blowing hot, so evacuated the system (R12), added the 134a reto fit couplings and pulled vacuum.
24hr no leaks.
Added 24oz 134a and gauge readings are displayed below.
No change in temp.

View attachment 1715910387

View attachment 1715910388
Wait so you just evacuated a 12 system and just put in 134 without changing the compressor and flushing all the oil? Did not change the dryer? It won't last the summer if that is the case. 12 oil dose not mix well with 134 it becomes acidic and will cause the system to fail.

24 oz of 134 is not enough charge unless your system only took 30 oz of 12.