Do I need to adjust valves with hyd. lifters?

One more thing to add here....if you're running some sort of anti pump up lifter, they adjust from a VERY light preload to a very small amount (about .002") of lash like a solid. A lot of people make the mistake of adjusting those like a standard hydraulic lifter and that's incorrect.
Thanks for the info Rusty, I have never heard this before.