6. Cylinder duster is now a 340 ignition issues wants to start when you let up on the key
@Bugman posted this in another thread.
Position Z is J1 (power to key switch) an 18 gage Gray with red stripe fusible link. This is connected to both the battery and the alternator. ie. Its always hot.
Position L is S2 (starter relay from key switch) 18 gage yellow. This should have power when the key is in start.
Position Q is J3 (ignition start from key switch) 14 gage brown. This should have power when the key is in start.