Machine Shop Did not Shim Valve Springs
When replacing factory retainers, locks, and valves(especially valves that have a different style lock groove), the installed height and tip heights can often end up pretty far from factory dimensions.
Performance type valves will often also have margin thicknesses that can differ from factory pieces, adding to installed/tip height variances.